Terms & Conditions
By booking a CNG cylinder hydrotesting appointment or using our compliance tools, you agree to the statutory testing protocol, safety preparation requirements, and transparent payment rules below.
1. Scope of Statutory PESO Rule 35 Testing
Every Compressed Natural Gas (CNG) cylinder installed in a motor vehicle in India must undergo periodic hydrostatic stretch testing once every 3 years under Rule 35 of the Gas Cylinders Rules, 2016 and Indian Standard IS 8451.
Booking an appointment on HSR facilitates time-slot allocation at an independent PESO Form GCT authorized testing station or HSR’s own facility once activated. Final technical inspection, testing execution, Form C / digital endorsement, and brass compliance plate stamping are governed by statutory PESO rules.
2. Vehicle Preparation & Empty-Tank (<10% Pressure) Mandate
For technician safety and safe degassing/nitrogen purging inside the hydrotesting area, vehicles MUST arrive with near-empty CNG pressure (below 10% gauge pressure / reserve warning level).
- Carry the original Vehicle Registration Certificate (RC) and previous Form C / cylinder compliance plate details if available.
- Report any prior collision damage, abnormal gas odour, valve leakage, or unauthorized bracket welding at gate check-in.
- Arrive at least 15 minutes before your scheduled appointment window to avoid automated slot release or rescheduling delays.
3. Cylinder Rejection, Condemnation & Mandatory Safety Actions
If a cylinder fails visual corrosion checks, ultrasonic thickness verification, tare-weight loss tolerances, or the 300-bar water-jacket volumetric expansion test under IS 8451 / Gas Cylinders Rules 2016:
- The testing station is legally prohibited from issuing a pass certificate or stamping a compliance plate on a failed cylinder.
- Under statutory PESO norms, condemned cylinders must be rendered permanently unserviceable (valve destruction / piercing with owner acknowledgement) to prevent hazardous refilling at public CNG dispensers.
- Station hydrostatic testing fees cover the conducted inspection and laboratory pressure test regardless of PASS or CONDEMNED outcome.
4. Role as Booking Marketplace & Pricing Transparency
For onboarded independent PESO partner stations, HSR acts purely as an appointment scheduling, asset history, and verification facilitator. Each station independently sets its gate testing tariff displayed clearly before confirmation, separated transparently from any HSR online platform convenience fee or refundable advance.